Level 2 Help for RESYNC

INP

INP contains the name(s) of the input VICAR labelled dataset(s)


OUT

OUT contains the name(s) of the dataset(s) which will contain the output 
resynch'ed VICAR image.


SIZE

Standard VICAR size field


SL

Starting line


SS

Starting sample


NL

Number of lines


NS

Number of samples


SEARCH

This parameter specifies the range of offsets to be searched for maximum
correlation. The program will test all offsets (both left and right) that are
no greater than the value of SEARCH.


IGNORE

Often the edges of an image contain engineering or fill data that should not
be used to compute line to line correlation.  This parameter directs the program
to exclude this number of pixels from each side, when computing correlation
statistics.  IGNORE'd pixels are, however, resynched and included in the output
image.


MODULO

Often, it is known that resync'ing need be performed only at specific intervals
within the image. The MODULO parameter allow the user to specify that interval.
The RESYNC program tests all lines for resync'ing, finds the most appropriate
starting point for the resync'ing operation, then adjusts the shift only at
those lines that are at a multiple of the specified interval.
     The default value (1) permits adjustment of the shift at any line.