Level 2 Help for CCDNOISE

INP

 STRING COUNT=1
 The Light Transfer File created by LTGEN and MOMGEN containing
 area statistics for calculating the system gain constant K and
 the noise floor.


OUT

 STRING--OPTIONAL
 Mark-format data set with (line,sample) centers of rejected areas
 (see REJECT parameter).


PLOT

 STRING--OPTIONAL
 Output signal vs. noise plot file
 Print with PRINT/NOFEED option.
 E.g.   DCL PRINT/NOFEED CCDNOISE.PLT


TABLE

 STRING--OPTIONAL
 Output tab-delimitted ASCII table file containing, for each exposure
 level:
  exposure time in msec
  signal at reticle 1, 
  noise at reticle 1, 
  computed at noise reticle 1,
  ....,  
  signal at reticle 5, 
  noise at reticle 5,
  computed at noise reticle 5

 Reticle 1 is Upper left corner, 2 is upper right, 3 is lower left,
 4 is lower right, and 5 is the center of the image.


LIMIT

 REAL COUNT=0:2--OPTIONAL
 LIMIT=(loexp,hiexp)
 Only data in the Light Transfer File with exposures (in msec) between 
 these values are used for the calculations.


EXTEXPO

 INTEGER--OPTIONAL--For Galileo only
 Specifies exposure level number (1 thru number of inputs) at which 
 extended exposure mode frames begins.


REJECT

 INTEGER--OPTIONAL
 Reject areas with values differing from mean by more than 2-sigma.
 REJECT=0 No area rejection
       =1 Reject areas with bad system gain
       =2 Reject areas with bad noise floor
       =3 Reject areas with either term bad


DBUG

 KEYWORD--OPTIONAL.
 Specifies diagnostic printout.