Level 2 Help for MPFTPT1

INP

First left eye image, then right eye image.
 


OUT

First output: A REAL image containing the line disparity. This is the line in
the second input (right eye) which corresponds to the line in the first
input image (left eye).
Second output: A REAL image containing the sample disparity. This is the sample
in the second input (right eye) which corresponds to the sample in the first
input image (left eye).
Third output: A REAL image containing the normalized quality, 0 to 1.


NLW

Correlation size height. An odd number.
The number of lines correlated at one time.
Defaults to 9.


TEMPLATE

Correlation size. Odd number. Defaults to 23.
 


SEARCH

Correlation search area. Odd number. Defaults to 95.
SEARCH > TEMPLATE.


SHIFT

Line displacement of right image before correlation.
- is down, + is up. 
A shift were +1, means that the right image is shifted up one line to match
the left image before correlation begins.
Default shift is zero.


QUALITY

Minimum acceptable correlation quality. Zero to 1.0 .
Defaults to 0.5