Level 2 Help for VLOOKUP
INP
This specifies one to five input image files.
OUT
This specifies zero to five output image files.
SIZE
The standard SIZE parameter is: (SL,SS,NL,NS)
You can enter SL, SS, NL, and NS together as SIZE, OR enter the SL, SS, NL,
and NS parameters separately.
By default, the entire input image is used if these parameters are not
entered.
SL
See Help SIZE
SS
See Help SIZE
NL
See Help SIZE
NS
See Help SIZE
SB
Starting band to use in a multi-band input image.
NB
Number of bands for a multi-band output image.
LUTFILE
This specifies the optional lookup table file. If not entered, then the
lookup table must be specified using the TABLE parameter.
TABLE
This specifies that the lookup table will be the standard table of the
number specified. As a historical note, the tables in this program are
the pseudocolor tables of program IDX (previously, IDISPLAY).
COLUMN
This specifies which column of the table corresponds to which output image.
The nth value entered is the column for the nth output image. If both
COLUMN and TABLE are used, then COLUMN changes what part of the standard
table is used for each output accordingly.